000 01355nam a22001697a 4500
003 OSt
005 20160506145457.0
008 160506b xxu||||| |||| 00| 0 eng d
040 _cNational Acoustic Laboratories
245 _aRonda - pavement noise measurements
520 3 _aRoad traffic noise affects approximately 8 million people in Australia with 2 million seriously affected, far more than from other forms of transportation. As the principal source of road noise is from the tyre/pavement interface, it is important to understand and quantify pavement noise and to catalogue ongoing performance. A new instrument is now available in Australia for this work comprising a special purpose noise trailer. RONDA (ROad Noise Data Acquirer) is a CPX trailer conforming to international standard ISO/CD 11819-2 [1] intended for measuring road pavement noise. The trailer is of the open frame type without an enclosure and is the first of its kind in Australia. A description of the design of the trailer is provided together with the results of initial testing on asphalt pavements.
650 _aNoise measurements
700 _aMichael Gange ...[et.al]
773 0 _gAcoustics 2015 (15-18 November, 2015 : Hunter Valley)
856 _uhttp://dspace.nal.gov.au/xmlui/bitstream/handle/123456789/349/p6.pdf?sequence=1&isAllowed=y
942 _2udc
_cARTICLE
999 _c2543
_d2543